Smart Buildings
Indiana Data Centers Create New Demand for Power, Cooling and Equipment Monitoring
Published by IOT Indiana Research & Editorial Team

Indiana is in the early part of a data center build-out. Projects from hyperscale companies, along with utility plans to serve them, are changing how power, cooling and equipment are bought, installed and watched. The demand is real, but it is also uneven, and the people who benefit most are those who understand which measurements actually matter.
This article is written as a buyer and supplier guide. It covers what the grid numbers say, how new utility rules shape metering, which monitoring points deliver value, a worked cost example, and how Indiana vendors can find a place in the supply chain.
The scale of the load
Indiana Michigan Power has told regulators it expects Indiana peak load to exceed 7 gigawatts by 2030, compared with about 2.8 gigawatts today, with data centers driving much of that growth. Individual campuses are large on their own: Meta's planned Lebanon campus is described at one gigawatt. For comparison, one gigawatt is roughly the output of a large power plant unit.
These figures come from utility filings and company announcements, and forecasts like them change. Some proposed projects will be delayed, resized or cancelled. Still, planners at utilities, cities and suppliers are acting on them, and that makes the demand real even before every megawatt arrives.
How utility rules shape monitoring
Indiana has moved toward rules that make large customers responsible for the costs they cause. Reports on an I&M settlement describe an industrial power tariff that applies to new or expanded loads of at least 70 megawatts, or 150 megawatts aggregated across a company, and require those customers to pay for the grid upgrades needed to serve them. State legislation in 2025 also addressed large-load cost responsibility. Specific terms continue to be decided in proceedings before the Indiana Utility Regulatory Commission, and utilities differ, so operators should read their own tariff.
Whatever the exact terms, large-load contracts tend to create measurement obligations. Demand charges depend on peak draw measured over short intervals. Minimum take or contract capacity provisions require accurate tracking of actual usage against commitments. Power quality limits may apply. Interconnection agreements specify metering points, accuracy classes and data access. The result is that revenue-grade metering and well-managed data become a financial matter, not just an engineering preference.
What to monitor: a tiered approach
Data center operators sometimes over-instrument in some places and under-instrument in others. A tiered approach keeps spending sensible.
Tier 1: Protect uptime
These measurements prevent outages and should be reliable, redundant and alarmed.
- Utility feeds and main switchgear: voltage, current, frequency and breaker state.
- UPS and battery systems: state of charge, temperature and battery health indicators.
- Generators: start readiness, fuel level and transfer switch status.
- Cooling plant: supply and return temperature, flow, pressure and pump or chiller status.
- Leak detection under raised floors, near coolant distribution units and along liquid cooling lines.
- Fire detection and suppression status.
Tier 2: Manage cost and capacity
These measurements support planning and billing.
- Sub-metering at distribution boards, PDUs and, where valuable, individual racks or customer suites.
- Power factor and harmonics to avoid penalties and equipment stress.
- Water meters at intake, blowdown and makeup.
- Rack inlet temperature and humidity for airflow management.
Tier 3: Predict and optimize
These measurements deliver gains once the basics are in place.
- Vibration, bearing temperature and motor current on pumps, fans and chillers for condition-based maintenance.
- Thermal imaging or continuous temperature sensing at switchgear connections.
- Coolant quality sensors, such as conductivity and pH, in liquid cooling loops.
- Analytics that link weather, load and cooling energy to find savings.
| Monitoring point | Failure or cost it addresses | Typical response |
|---|---|---|
| Battery temperature and health | Unexpected UPS failure during an outage | Replace weak strings during planned windows |
| Chiller and pump vibration | Bearing wear causing unplanned cooling loss | Schedule repair before failure |
| Coolant distribution leak sensors | Fluid damage to servers | Isolate loop and dispatch technician |
| Switchgear connection temperature | Loose lug leading to arc fault or fire | Tighten or replace during maintenance |
| Peak demand metering | Demand charges set by brief spikes | Shift or cap non-critical loads |
| Water intake and blowdown | Excess consumption and treatment cost | Adjust cycles of concentration |
A worked example: the cost of a missed warning
The figures here are hypothetical and meant to show the reasoning. They do not represent any real facility.
Imagine a 20 megawatt data hall with a cooling plant of six chillers and twelve circulation pumps. Operators install vibration and temperature sensors on every pump and chiller motor for a total sensor, gateway and software cost of about $90,000, with an annual service fee of $25,000.
- In the first year, the system flags a pump bearing trending toward failure. The team swaps the pump during a planned window, with a repair cost of about $6,000.
- Without the warning, assume the pump fails in service, causing a partial cooling shortfall that forces temporary load reduction. If the affected capacity earns $3,000 per hour in service revenue and the incident lasts five hours, the direct loss is $15,000, before any contractual penalties or customer goodwill effects.
- A single avoided incident does not repay the program, but a few avoided incidents over several years, along with fewer emergency call-outs and longer equipment life, can.
The honest conclusion is that value depends on avoided events, which are hard to prove. Operators build the case by logging every alert, the action taken and the cost avoided, so after twelve months they have evidence rather than guesses.
Cooling in transition
Cooling approaches are changing quickly. Traditional air cooling with chilled water remains common, but higher rack densities push operators toward rear-door heat exchangers, direct-to-chip liquid cooling and in some cases immersion. Each approach has its own monitoring needs.
- Air cooling: focus on temperature and airflow distribution, containment integrity and filter condition.
- Direct-to-chip liquid: focus on flow, differential pressure, coolant temperature, fluid quality and leak detection.
- Immersion: focus on fluid level, temperature and purity, plus handling and safety procedures.
Water use depends heavily on whether a site uses evaporative cooling, dry coolers or a hybrid. Good metering lets operators compare designs using real data, and it supports conversations with local utilities and residents.
Where Indiana vendors can fit
The supply chain for data center monitoring includes global manufacturers of meters, sensors and building controls, large engineering firms and national service companies. Local businesses win work in these ways:
- Installation and commissioning. Electrical and controls contractors who can install sensors, test loops and document results.
- Calibration and testing. Labs that service meters, thermal cameras and sensors on a schedule.
- Maintenance services. Technicians trained on chillers, pumps, switchgear and building automation.
- Fabrication. Panels, enclosures, mounting hardware and custom piping accessories.
- Systems integration. Firms that connect meters and sensors to monitoring platforms through standard protocols such as Modbus, BACnet and OPC UA, and that handle network segmentation.
- Training. Programs that build the pipeline of operations technicians.
Our coverage of Meta's Lebanon campus and of how Indiana data center demand affects ratepayers looks at these topics from the project and bill-payer sides.
Questions to put to your utility
Before specifying meters and data systems, operators and their engineers should get written answers from the serving utility. The answers decide what you must measure and who owns the data.
- Which meter is the billing meter, and what accuracy class and communication interface does it use?
- How is peak demand calculated: the highest 15-minute interval, a rolling window, or a coincident peak with the system?
- Are there minimum demand or contract capacity charges, and how are ramp-up periods handled while a campus is still filling with servers?
- What power quality limits apply, and who pays for corrective equipment if harmonics exceed them?
- Can the customer receive interval data in near real time, and in what format?
- What curtailment or demand response terms exist, and what must be measured to prove participation?
Operators that cannot answer these questions before construction often discover them in their first large bill. Putting a sub-metering plan in place during design is far cheaper than retrofitting one into live switchgear.
Buying checklist for operators
- Define the decision each sensor supports. If no one will act on a measurement, do not buy it yet.
- Specify accuracy and calibration needs. Revenue-grade metering has different requirements from trending sensors.
- Insist on open protocols. Avoid lock-in by requiring support for standard interfaces and data export.
- Plan the network. Separate monitoring from production networks, and document remote access.
- Test alarms. Run realistic failure drills to confirm alerts reach the right people and are not drowned out by nuisance alarms.
- Budget for lifecycle. Sensors drift and software needs updates, so include calibration and support in total cost.
- Keep an evidence log. Record alerts, actions and outcomes to prove value.
Risks and open questions
Several unknowns affect this market. Forecasts for AI-driven load growth may fall short or overshoot. Hardware that uses less energy per computation could slow demand. Regulators and utilities are still working out cost allocation, and ratepayer advocates have argued about whether existing customers are adequately protected, while utilities and data center companies point to commitments that large customers will carry their share of costs. Readers should consult the filings directly.
Supply constraints also matter. Transformers, switchgear and generators have had long lead times in recent years, which affects schedules and favors operators who plan early. Skilled labor is similarly tight. For monitoring suppliers, that means winning work often depends on staffing and delivery reliability as much as on technology.
The bottom line
Data centers are turning Indiana power and cooling systems into a large, measurable operating environment. The strongest demand will go to measurements that protect uptime, support the tariff and billing structure, and extend the life of expensive equipment. Operators should buy against decisions, not features, and Indiana suppliers should focus on installation quality, calibration, maintenance and reliable data. Done well, monitoring is a modest line item that protects very large investments.